Brand Name :HNMC
Model Number :HES-20
Place of Origin :China
MOQ :1
Price :Negotiable
Supply Ability :10 sets per month
Delivery Time :30-45 days
Packaging Details :Wooden Package
Accuracy Class :0.02S (SCT)
Accuracy class :0.05S (SPT)
Rated Primary Current :1-3200A
Rated Secondary Current :5A, 1A
Operation range :1-120% Un
Rated Frequency :50 or 60HZ
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

0.02S Standard Current Transformer CT PT Test Equipment Test System

Measure Item Test Range

CT accuracy test

Rated primary current range: 1A-3200A
Rated secondary current: 5A, 1A
Operation range: (1%-120%).In

PT accuracy test

Rated primary voltage (kV): 6, 6/√3, 10, 10/√3, 15, 15/√3, 22, 22/√3, 35, 35/√3, 40.5, 40.5/√3
Rated secondary voltage (kV): 0.1, 0.1/√3, 0.11, 0.11/√3
Operation range: (20%-120%).Un

Accuracy class of the measure equipments:

Product Description Accuracy Class
Standard CT (with Current Source) ±0.02S%
Standard PT (with Voltage Source) ±0.05%
CT Burden ±3%
PT Burden ±3%
Transformer Tester (Calibrator) ±1%
Control bench


Technical Index of HES-1C Transformer Tester

Measure item: Ratio errors & Phase errors of the CT and PT
Rated current: 5A, 1A
Rated voltage: 100V,110V,120V
Multiplier: 1/√3,1/3,1,1.5,2
Accuracy class: ±1%
Operation range: (1%-120%).In, (20%-120%).Un
Frequency: 50Hz
Ratio error range: ±0.0001% ~ ±19.99%(three positions: 1.999‰, 19.99‰, 199.9‰.
Minimum resolution:0.0001%.
Phase error range: 0.01' ~ ±900'(three positions: 9.00',90.0',900')
Minimum resolution: 0.01'
Impedance range: 0.001Ω~ 19.99Ω.
Minimum resolution: 0.001Ω.
Admittance range: 0.001 ms ~ 19.99 ms.
Minimum resolution:0.001 ms.
Alarm Function: Provided the sound & light alarm function when the polarity abnormal or ratio inconsistent.

Input Load:

- On Standard CT secondary side: ≈0.11Ω, COSφ≈1.0

- On Test Object CT secondary side: ≈0.003Ω, COSφ≈1.0

- On Standard PT secondary side: ≈0.05VA (100V)

Communication Interface: Provided the RS232 serial communication interface
Display model: LED
Power supply: AC 220V±10%, 50Hz
Power consumption: < 20VA

Technical Index of FY47-49 CT Burden

Rated Current: 5A, 1A

Rated Burden:

I=5A:

COSФ=0.8: 2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 2.5/3.75/5/6.25/7.5/10VA

I=1A:

COSФ=0.8: 0.1/0.15/0.2/0.25/0.3/0.4/0.5/0.6/0.8/1.0/1.2/1.6/2.0/2.4VA

2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA

COSФ=1.0: 0.1/0.15/0.2/0.25/0.3/0.4/2.5/3.75/5/6.25/7.5/10VA

Accuracy Class: ±3%
Operation Range: (1%-120%). In
Frequency: 50Hz
Withstand Voltage: 2kV/1min
Insulation: Air
Operating Model: Short-time

High-current Test Cables

Cables includes: 3000A(600mm2) x 3m x 1pc, 1000A(200mm2) x 3m x 1pc

500A(100mm2) x 3m x 2pcs, 250A(50mm2) x 3m x 2pc

Technical Index of HLS-30G2 Standard CT with current generator

Rated Primary Current(A):

1,1.5,2,2.5,3,4,5, 7.5, 10, 12.5, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 125, 150, 160, 200, 250, 300, 315, 350, 400, 450, 500, 600, 630, 700, 750, 800, 900, 1000, 1200, 1250, 1400, 1500, 1600, 1800, 2000, 2500, 3000, 3150, 3200A
Rated Secondary Current: 1A
Rated Current Ratio: 1A~3200A/5A, 1A~3200A/1A
Accuracy Class: 0.02S% or higher accuracy (optional)
Rated Secondary Burden: 0.2Ω(Burden is 5VA at I2 = 5A, Burden is 0.2VA at I2 = 1A )
Power Factor: COSΦ=1.0
Operating Range: (1%-120%). In

Connection Mode:

Fixed connection terminals at Pri.current range is 1A-450A

Pass-through connection with 2 turns at Pri.current range is 500A-900A

Pass-through connection with 1 turn at Pri.current range is 1000A-3200A

Product Structure: With Current Source
Input Voltage: AC 0-250V
Capacity of Current Generator: ~20kVA
Frequency: 50/60Hz
Voltage Level: AC 600V
Withstand Voltage: 2000V 1min
Insulating Medium: Air

Technical Index of FY95 PT Burden box

Products Description: Voltage Transformer Burden
Products Model: FY95
Rated Voltage: 100V, 100/√3V, 110V, 110/√3V
Power Factor: COSФ=0.8
Rated Burden (VA): 1.25VA, 2.5VA, 5VA, 10VA, 20VA, 40VA, 80VA
Total Burden: 158.75VA
Accuracy Class: ±3%
Operation Range: (20%-120%). Un
Frequency: 50Hz or 60HZ
Withstand Voltage: 2kV/1min
Insulation: Air
Operating Model: Short-time
Operating Condition: Temperature: 10 oC~+40 oC
Relative Humidity (RH): up to 85% (max 90%)

Technical Index of HJS-40G3 Standard PT (with Voltage Generator)

Rated Primary Voltage: 6kV, 6/√3kV, 10kV, 10/√3kV, 15kV, 15/√3kV, 22kV, 22/√3kV, 35kV, 35/√3kV, 40.5kV, 40.5/√3kV
Rated Secondary Voltage: 100V, 100/√3V, 110V, 110/√3V
Rated Voltage Ratio (kV):

6/0.11kV, 6/√3/0.11/√3kV, 6/0.1kV, 6/√3/0.1/√3kV

10/0.11kV, 10/√3/0.11/√3kV, 10/0.1kV, 10/√3/0.1/√3kV

22/0.11kV, 22/√3/0.11/√3kV, 22/0.1kV, 22/√3/0.1/√3kV

35/0.11kV, 35/√3/0.11/√3kV, 35/0.1kV, 35/√3/0.1/√3kV

40.5/0.11kV, 40.5/√3/0.11/√3kV, 40.5/0.1kV, 40.5/√3/0.1/√3kV

Accuracy Class: 0.05% (higher accuracy optional)
Rated Secondary Burden: 0.2VA(100V, 110V), 0.07VA(100/√3V, 110/√3V)
Power Factor: COSΦ=1.0
Operating Range: (20%-120%). Un
Frequency: 50Hz or 60Hz
Insulation: Epoxy resin casting or Oil
Products Structure: With voltage source
Input Voltage of the Voltage Source: AC 0-250V