Zhengzhou Great Electric Co.,Ltd.

Grow with our partner n the wordwide

Manufacturer from China
Site Member
5 Years
Home / Products / CT PT Test Equipment /

Portable 0.05 Class Transformer Ratio Tester For Field Examianation

Contact Now
Zhengzhou Great Electric Co.,Ltd.
City:zhengzhou
Province/State:henan
Country/Region:china
Contact Person:MrTony Han
Contact Now

Portable 0.05 Class Transformer Ratio Tester For Field Examianation

Ask Latest Price
Video Channel
Brand Name :HNMC
Model Number :MCVT-01D
Place of Origin :China
MOQ :1
Price :Negotiable
Supply Ability :20 Sets Per Month
Delivery Time :30-45 days
Packaging Details :Carton package
Application :Field Testing
Test function :Ratio, Ratio Error, Phase Error, Polarity...etc
Accuracy :0.05% (Ratio test)
Ratio test range :1-40000
Dimension :367*292*150mm
Weight :<8kgs
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Portable CT PT Test Equipment MCVT-01D

Major Technical Parameters

Item Description
Power Supply AC220V±10% 50/60HZ
Output 0-180Vrms, 12Arms, 36A (peak value)
Voltage test accuracy ±0.2%
Ratio error test (metering CT) ±0.2%
Secondary resistance range/accuracy 0~300Ω / 0.2%±2mΩ
Secondary burden range/accuracy 0~1000VA / 0.2%±0.02VA
Phase test range/accuracy 0-360°/ ±2min, resolution 0.5min
PT ratio range/accuracy 1-40000 / ±0.05%
CT ratio range/accuracy 1-40000 / ±0.05%
Dimension & Weight Size:367mm × 292mm × 150mm ,weight:<8kgs (including accessories)

Features

1. CT test

Excitation (VA) characteristic

Ratio test

Polarity Test

Secondary winding resistance test

Secondary burden test

Ratio error

Phase error test

2. PT test (electro-magnetic type)

Excitation (VA) characteristic

Ratio Test

Polarity test

Secondary winding resistance test

Secondary burden test

Phase error test

3. Automatically provide CT&PT parameters including knee point voltage/current, 10% & 5% error curve,

ALF (accuracy limit factor), FS (Instrument security factor), secondary time constant (Ts), Remanence

coefficient (Kr), saturated inductance, and etc…

4. Adopt low frequency method test principle and can perform the test of CT with knee point up to 30KV

5. CT admittance test

6. Adopt popular square wave method and can get more perfect excitation curve

7. Big storage space can ensure saving of more than 100000 test data.

8. Directly generate Excel report after finishing test, also can directly printer

9. Simple operation: one-key finish CT winding resistance test & excitation test & ratio test & polarity test;

except burden test, other tests all adopt same wiring


Inquiry Cart 0